| CCLP1 PD | Core LPG for Permanent Dwellings. |
| CCLP1 RPH | Core LPG for Residential Park Homes. |
| CCLP1 LAV | Core LPG for Leisure Accommodation Vehicles covering Road Vehicles including Caravan and Motor Caravan, typical appliances also required HTRLP3, REFLP2, WATLP2, WAHLP1, CKR1. Also covers Non-Road Vehicles such as Caravan Holiday Home, typical appliances also required HTRLP2, CKR1, WAT1, CENWAT. |
| CCLP1 B | Core LPG for Boats. Covers vessels not requiring a load line certificate and which are Boats hired out in the course of a business eg used for holiday accommodation; Boats used solely or primarily for domestic or residential purposes eg houseboats or barges; Boats made available to the public in the course of a business eg floating restaurants or public houses. |
| CCLP1 EP | Core LPG for Installation of external pipework from storage vessel to emergency isolation valve at point of entry to premises. Limited Scope Assessment. |
| VESLP1 | Service pipework gas storage vessel connections, controls, safety requirements, sizing, installing, testing, and purging external above ground (35mm copper or 1¼ steel) and un-jointed below ground PE pipework ≤ 32mm with pipe volumes ≤ 0.035 m3 for single LPG supplies. |
| VESLP2 | Service pipework gas storage vessel connections from vapour valve outlet including controls, safety requirements, sizing, installing, testing, and purging of single and multiple supply jointed above ground and below ground PE pipework within the scope of Liquid Gas UK CoP 22. |
| EFJLP1 | Gas safety competence in electro-fusion jointing of PE pipework and fittings. |
| CCLP1 MC | Core competencies required for LPG mobile cabinet heaters. |
| CABLP1 | Exchange, commission, disconnect, service, repair and break down domestic butane gas fired mobile Radiant, Flame Effect and Catalytic mobile cabinet heaters and single bottle supply leisure equipment including, barbecues, greenhouse heaters, gas lighting, flambeaus and patio heaters. |
| CCLP1 EPC | Installation and commissioning of service pipework; single and multiple supplies; Re-connection and commissioning of existing installation pipework; Installation and commissioning of prefabricated LPG meter installations; Re-lighting of domestic and commercial gas appliances including all IP and LP LPG installations for PDs, RPHs, LAVs and small non-domestic premises.
Total volume of the installation ≤ 0.02m3 and capacity of the meter ≤ 6m3/h (where fitted). |
| LEILP1 | Exchange, disconnection, service, repair, break down and commission domestic butane and propane gas fired leisure equipment connected to single bottle supply including barbecues, greenhouse heaters, gas lighting, flambeaus and patio heaters. For equipment connected to fixed installation pipework use LEI1. |
| HTRLP2 | Install, exchange, disconnect, service, repair, break down and commission LPG closed flue gas fires such as Widney Leisure. |
| HTRLP3 | Install, exchange, disconnect, service, repair, break down and commission LPG caravan space heaters. |
| REFLP2 | Install, exchange, disconnection, service, repair, break down and commission domestic LPG space refrigerators in motorised and touring caravans and boats such as the Electrolux RM 4230 and RM 4231. |
| WATLP2 | Install, exchange, commission, disconnect, maintain, service, repair and break down domestic LPG gas water heating appliances in motorised and touring caravans such as Cascade Rapide, Cascade Rapide GE, Belling Malaga and Malaga ‘E’ |
| WAHLP1 | Install, exchange, disconnect, service, repair, break down and commission LPG warm air heating systems in boats and LAVs such as the Whispaire P4 Carver Marine Warm Air Heating System. |